Flat Non-Rewirable Two Pole Plug with supply cord (max. 2.5A)
|
PLUG TOP/PLUG (a) Plug
|
makes a detachable connection between the contacts of a socket-outlet and the conductors of a flexible cord; has insulating sleeves on the line and neutral plug pins for insertion into a socket-outlet; and has a maximum rating of 15 A
|
MS 1578:2003
|
BS EN 50075:1991
|
|
13 A Fused Plug
|
PLUG TOP/PLUG (a) Plug
|
makes a detachable connection between the contacts of a socket-outlet and the conductors of a flexible cord; has insulating sleeves on the line and neutral plug pins for insertion into a socket-outlet; and has a maximum rating of 15 A
|
MS 589-1:2011
|
BS 1363:PT.1:1995 +A1 A2 A3
|
|
15 A Plug
|
PLUG TOP/PLUG (a) Plug
|
makes a detachable connection between the contacts of a socket-outlet and the conductors of a flexible cord; has insulating sleeves on the line and neutral plug pins for insertion into a socket-outlet; and has a maximum rating of 15 A
|
MS 1577:2003
|
No corresponding international standard
|
|
Appliance Coupler
|
PLUG TOP/PLUG (b) Coupler
|
is for attachment to a flexible cord; and makes a detachable connection between the conductors of the cord and the pins or contacts of any low voltage appliance or equipment of a type intended or generally used for household applications
|
MS IEC 60320-1:2010
|
IEC 60320-1:2007
|
|
Interconnection Coupler
|
PLUG TOP/PLUG (b) Coupler
|
is for attachment to a flexible cord; and makes a detachable connection between the conductors of the cord and the pins or contacts of any low voltage appliance or equipment of a type intended or generally used for household applications
|
MS IEC 60320-1:2010; MS IEC 60320-2-2:2011 (confirmed 2015)
|
IEC 60320-1:2007; IEC 60320-2-2:1998
|
|
Adaptor (Multiways)
|
PLUG TOP/PLUG (c) Adaptor
|
extends supply from a socket-outlet; incorporates one or more integral socket-outlets; and has insulating sleeves on the line and neutral plug pins
|
MS 589-3:2018
|
BS 1363 PT.3:1995 +A1 A2 A3
|
|
Integrated Adaptor
|
PLUG TOP/PLUG (c) Adaptor
|
extends supply from a socket-outlet; incorporates one or more integral socket-outlets; and has insulating sleeves on the line and neutral plug pins
|
MS 1144:2017
|
BS 5733:2010+A1 2014
|
|
Travel Adaptor
|
PLUG TOP/PLUG (c) Adaptor
|
extends supply from a socket-outlet; incorporates one or more integral socket-outlets; and has insulating sleeves on the line and neutral plug pins
|
No corresponding MS
|
IEC 60884-1:2006; IEC 60884-2-5:1995
|
|
Electrical Connector (connecting device)
|
PLUG TOP/PLUG (d) Connector
|
Connecting devices for the connection of two or more electrical copper conductors
|
MS IEC 60998-1:2005
|
IEC 60998-1:2002
|
|
Connecting device with screw type clamping unit
|
PLUG TOP/PLUG (d) Connector
|
Connecting devices for the connection of two or more electrical copper conductors
|
MS IEC 60998-1:2005; MS IEC 60998-2-1:2005
|
IEC 60998-1:2002; IEC 60998-2-1:2002
|
|
Connecting device with screw-less type clamping unit
|
PLUG TOP/PLUG (d) Connector
|
Connecting devices for the connection of two or more electrical copper conductors
|
MS IEC 60998-1:2005; MS IEC 60998-2-2:2005
|
IEC 60998-1:2002; IEC 60998-2-2:2002
|
|
Connecting device with insulation-piercing clamping units
|
PLUG TOP/PLUG (d) Connector
|
Connecting devices for the connection of two or more electrical copper conductors
|
MS IEC 60998-1:2005; MS IEC 60998-2-3:2005
|
IEC 60998-1:2002; IEC 60998-2-3:2002
|
|
Twist-on connecting device
|
PLUG TOP/PLUG (d) Connector
|
Connecting devices for the connection of two or more electrical copper conductors
|
MS IEC 60998-1:2005; MS IEC 60998-2-4:2005
|
IEC 60998-1:2002; IEC 60998-2-4:2002
|
|
Connecting boxes
|
PLUG TOP/PLUG (d) Connector
|
Connecting devices for the connection of two or more electrical copper conductors
|
MS 1873:2005; MS 1873-22:2006
|
IEC 60670-1:2002 with modification; IEC 60670-22:2002 with modification
|
|
General Purpose Switch
|
SWITCH AND DIMMER
|
is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A
|
MS IEC 60669-1:2012
|
IEC 60669-1:2007
|
|
Door Bell & Chime
|
SWITCH AND DIMMER
|
is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A
|
MS IEC 61558-1:2005; MS IEC 61558-2-8:2007
|
IEC 61558-1:2009; IEC 61558-2-8:2010
|
|
Electronic Switch
|
SWITCH AND DIMMER
|
is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A
|
MS IEC 60669-1:2012; MS IEC 60669-2-1:2012
|
IEC 60669-1:2007; IEC 60669-2-1:2009
|
|
Remote-control Switch
|
SWITCH AND DIMMER
|
is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A
|
MS IEC 60669-1:2012; MS IEC 60669-2-2:2012
|
IEC 60669-1:2007; IEC 60669-2-2:2006
|
|
Time Delay Switch
|
SWITCH AND DIMMER
|
is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A
|
MS IEC 60669-1:2012; MS IEC 60669-2-3:2012
|
IEC 60669-1:2007; IEC 60669-2-3:2006
|
|
Cooker Control Unit
|
SWITCH AND DIMMER
|
is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A
|
No corresponding MS
|
BS 4177:1992
|
|
Electric Shaver Socket Outlet
|
SOCKET OUTLET (a) Socket Outlet
|
is for fixing at a point at which fixed wiring terminates; provides a detachable connection with the pins of a plug; has two or more contacts; has a maximum rating of 15 A; with switch and without switch socket outlet
|
MS IEC 61558-1:2005; MS IEC 61558-2-5:2006
|
IEC 61558-1:2009; IEC 61558-2-5:2010
|
|
13A Switch & unswitch socket outlet
|
SOCKET OUTLET (a) Socket Outlet
|
is for fixing at a point at which fixed wiring terminates; provides a detachable connection with the pins of a plug; has two or more contacts; has a maximum rating of 15 A; with switch and without switch socket outlet
|
MS 589-2:2018
|
BS 1363:PT 2:1995 +A1 A2 A3
|
|
15A socket outlet & Plug
|
SOCKET OUTLET (a) Socket Outlet
|
is for fixing at a point at which fixed wiring terminates; provides a detachable connection with the pins of a plug; has two or more contacts; has a maximum rating of 15 A; with switch and without switch socket outlet
|
MS 1577:2003
|
No corresponding international standard
|
|
Portable 2 pin socket outlet class II
|
SOCKET OUTLET (a) Socket Outlet
|
is for fixing at a point at which fixed wiring terminates; provides a detachable connection with the pins of a plug; has two or more contacts; has a maximum rating of 15 A; with switch and without switch socket outlet
|
MS 1579:2003
|
No corresponding international standard
|
|
Portable cable reel
|
SOCKET OUTLET (b) Portable
|
A device comprising a flexible cable or cord attached to a reel so constructed that the flexible cable may be completely wound onto the reel, and provided with a plug and one or more socket outlets
|
MS 1141:2006
|
IEC 61242:2008 with modification
|
|
Lamp holder for tubular fluorescent lamp
|
FLUORESCENT LAMPHOLDER / STARTER HOLDER (a) Lamp Holder
|
Holds tubular fluorescent lamp but does not include a lamp holder which by design is restricted to specific appliances
|
MS IEC 60400:2006
|
IEC 60400:2004
|
|
Starter holder for tubular fluorescent lamp
|
FLUORESCENT LAMPHOLDER / STARTER HOLDER (b) Starter Holder
|
To hold a glow starter but does not include a starter holder which by design is restricted to specific appliances
|
MS IEC 60400:2006
|
IEC 60400:2004
|
|
Ceiling Rose
|
CEILING ROSE
|
A terminal for connection to a lamp holder via a cable
|
MS 770:1982 (confirmed 2006)
|
BS 67:1969
|
|
Edison Screw Lamp holder
|
CEILING ROSE
|
Edison Screw Lamp holder with Edison screw thread E14, E27 and E40, designed for holding and connecting to the supply of lamps
|
MS IEC 60238:2008
|
IEC 60238:2004
|
|
Bayonet cap Lampholder
|
BAYONET CAP and MULTIWAYS ADAPTOR
|
holds a bayonet cap lamp, bayonet cap adaptor; does not include a lamp holder restricted to specific appliances or for incorporation in industrial equipment
|
No corresponding MS
|
IEC 61184:2008+A1
|
|
Bayonet Lamp Adaptor
|
BAYONET CAP and MULTIWAYS ADAPTOR
|
holds a bayonet cap lamp, bayonet cap adaptor; does not include a lamp holder restricted to specific appliances or for incorporation in industrial equipment
|
MS 769:1982 (confirmed 2013) with IEC 61184:2008
|
IEC 61184:2008 with modification
|
|
Fixed general purpose Luminaires (excluding Tube/Bulb); Batten Luminaires (excluding Tube/Bulb); Luminaires with self-ballasted fluorescent lamp
|
LAMP FITTING (a) Luminaires
|
provides illumination; incorporate electric light sources for operation from supply voltage up to 1000V
|
MS IEC 60598-1:2012; MS IEC 60598-2-1:1997 (confirmed 2015)
|
IEC 60598-1:2008; IEC 60598-2-1:1979
|
|
Recessed Luminaires (excluding Tube/Bulb)
|
LAMP FITTING (a) Luminaires
|
provides illumination; incorporate electric light sources for operation from supply voltage up to 1000V
|
MS IEC 60598-1:2012; MS IEC 60598-2-2:1998 (confirmed 2011)
|
IEC 60598-1:2008; IEC 60598-2-2:1997
|
|
Glow-starter for tubular fluorescent
|
LAMP FITTING (b) Glow Starter
|
is for starting pre-heat type fluorescent lamps; is a glow-start type; has an enclosure of insulating material; holds a light source or bulb
|
MS IEC 60155:1996
|
IEC 60155:2006
|
|
with Edison screw or bayonet caps
|
LAMP FITTING (c) Self-ballasted Compact Fluorescent Lamp (CFL)
|
Lamp which cannot be dismantled without being permanently damaged, provided with a lamp cap incorporating a light source and any elements necessary for starting and stable operation
|
MS IEC 60968:2006 (confirmed 2011); MS IEC 60969:2006 (confirmed 2015)
|
IEC 60968:1999; IEC 60969:2001
|
|
MS IEC 61347-1:2012; MS IEC 61347-2-13:2012
|
LAMP FITTING (d) LED Lighting
|
Lamp controlgear: Particular requirements for d.c. or a.c. supply electronic controlgear for LED modules
|
IEC 61347-1:2010; IEC 61347-2-13:2006
|
|
|
MS IEC 60838-1:2008; MS IEC 60838-2-2:2008
|
LAMP FITTING (d) LED Lighting
|
Lampholder (Connectors for LED-modules)
|
IEC 60838-1:2004; IEC 60838-2-2:2006
|
|
|
MS IEC 62031:2011 with MS IEC 60061-1:2005
|
LAMP FITTING (d) LED Lighting
|
Self-ballasted LED Modules for general Lighting services by voltage > 50V
|
IEC 62031:2008+A1 A2 with IEC 60061-1:2005
|
|
|
MS IEC 62776:2017
|
LAMP FITTING (d) LED Lighting
|
Self-ballasted double capped LED Lamps for general lighting services by voltage > 50V (to retrofit linear fluorescent lamp)
|
IEC 62776:2014
|
|
|
MS IEC 62560:2012
|
LAMP FITTING (d) LED Lighting
|
Self-ballasted single capped LED-lamps for general lighting services by voltage > 50V
|
IEC 62560:2011
|
|
|
Capacitors for use in tubular fluorescent lamps and other circuits
|
CAPACITOR for FLUORESCENT LAMP
|
Is used together with a ballast in a lamp circuit
|
MS IEC 61048:2006; MS IEC 61049:1999 (confirmed 2015)
|
IEC 61048:1999; IEC 61049:1991
|
|
Magnetic Ballast for tubular fluorescent lamp
|
BALLAST / CONTROL GEAR / DRIVER FOR LAMP (a) Ballast
|
is for controlling the magnitude of current flowing through the discharge path of a fluorescent lamp; is of the independent or built-in type intended for use with luminaires; or is of the integral type; or is of the adaptor type
|
MS IEC 61347-1:2012; MS IEC 61347-2-8:2003; MS 141:2014 with MS IEC 60921:2013
|
IEC 61347-1:2010; IEC 61347-2-8:2000; IEC 60921:2006 with modification
|
|
Electronic Ballast for fluorescent lamp
|
BALLAST / CONTROL GEAR / DRIVER FOR LAMP (a) Ballast
|
is for controlling the magnitude of current flowing through the discharge path of a fluorescent lamp; is of the independent or built-in type intended for use with luminaires; or is of the integral type; or is of the adaptor type
|
MS IEC 61347-1:2012; MS IEC 61347-2-3:2003; MS IEC 60929:2008 with MS IEC 61000-3-2:2014
|
IEC 61347-1:2010; IEC 61347-2-3:2000; IEC 60929:2006 with IEC 61000-3-2:2009
|
|
Control Gear
|
BALLAST / CONTROL GEAR / DRIVER FOR LAMP (b) Control Gear
|
General safety for lamp controlgear for use on dc supply up to 250V and or ac supply up to 1000V
|
MS IEC 61347-1:2012
|
IEC 61347-1:2010
|
|
Residual Current Circuit Breaker (RCCB)
|
CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (a) Residual Current Device (RCD)
|
isolates or initiates a tripping signal to isolate a low-voltage supply to protected circuits; has a rated residual current less than 300mA for fixed wiring or 10mA for other devices; has a rated load current not exceeding 125A for fixed wiring or 20A for other devices
|
MS IEC 61008-1:2012; MS IEC 61008-2-1:2003 or MS IEC 61008-1:2012; MS IEC 61008-2-2:2003
|
IEC 61008-1:2010; IEC 61008-2-1:1990 or IEC 61008-1:2010; IEC 61008-2-2:1990
|
|
Residual Current Breaker with Overcurrent Protection (RCBO)
|
CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (a) Residual Current Device (RCD)
|
isolates or initiates a tripping signal to isolate a low-voltage supply to protected circuits; has a rated residual current less than 300mA for fixed wiring or 10mA for other devices; has a rated load current not exceeding 125A for fixed wiring or 20A for other devices
|
MS IEC 61009-1:2012; MS IEC 61009-2-1:2003 or MS IEC 61009-1:2012; MS IEC 61009-2-2:2003
|
IEC 61009-1:2010; IEC 61009-2-1:1991 or IEC 61009-1:2010; IEC 61009-2-2:1991
|
|
Miniature Circuit Breaker (MCB) for ac supply
|
CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse
|
is an enclosed air-break switch; opens a low voltage circuit automatically under pre-determined conditions of overcurrent; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA
|
MS IEC 60898-1:2007
|
IEC 60898-1:2003
|
|
Miniature Circuit Breaker (MCB) for ac & dc supply
|
CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse
|
is an enclosed air-break switch; opens a low voltage circuit automatically under pre-determined conditions of overcurrent; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA
|
MS IEC 60898-2:2007
|
IEC 60898-2:2003
|
|
Fuse Base & Carrier up to 32A
|
CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse
|
is an enclosed air-break switch; opens a low voltage circuit automatically under pre-determined conditions of overcurrent; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA
|
MS IEC 60269-1:2011; MS IEC 60296-2:2011
|
IEC 60269-1:2006; IEC 60269-2:2006
|
|
Fuse/Fuse Link up to 63A
|
CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse
|
is an enclosed air-break switch; opens a low voltage circuit automatically under pre-determined conditions of overcurrent; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA
|
MS IEC 60269-2:2011; MS IEC 60269-3:2011
|
IEC 60269-2:2006; IEC 60269-3:2010
|