List of Regulated Electrical Equipment

Equipment Name Category Description National Standard International Standard
Flat Non-Rewirable Two Pole Plug with supply cord (max. 2.5A) PLUG TOP/PLUG (a) Plug makes a detachable connection between the contacts of a socket-outlet and the conductors of a flexible cord; has insulating sleeves on the line and neutral plug pins for insertion into a socket-outlet; and has a maximum rating of 15 A MS 1578:2003 BS EN 50075:1991
13 A Fused Plug PLUG TOP/PLUG (a) Plug makes a detachable connection between the contacts of a socket-outlet and the conductors of a flexible cord; has insulating sleeves on the line and neutral plug pins for insertion into a socket-outlet; and has a maximum rating of 15 A MS 589-1:2011 BS 1363:PT.1:1995 +A1 A2 A3
15 A Plug PLUG TOP/PLUG (a) Plug makes a detachable connection between the contacts of a socket-outlet and the conductors of a flexible cord; has insulating sleeves on the line and neutral plug pins for insertion into a socket-outlet; and has a maximum rating of 15 A MS 1577:2003 No corresponding international standard
Appliance Coupler PLUG TOP/PLUG (b) Coupler is for attachment to a flexible cord; and makes a detachable connection between the conductors of the cord and the pins or contacts of any low voltage appliance or equipment of a type intended or generally used for household applications MS IEC 60320-1:2010 IEC 60320-1:2007
Interconnection Coupler PLUG TOP/PLUG (b) Coupler is for attachment to a flexible cord; and makes a detachable connection between the conductors of the cord and the pins or contacts of any low voltage appliance or equipment of a type intended or generally used for household applications MS IEC 60320-1:2010; MS IEC 60320-2-2:2011 (confirmed 2015) IEC 60320-1:2007; IEC 60320-2-2:1998
Adaptor (Multiways) PLUG TOP/PLUG (c) Adaptor extends supply from a socket-outlet; incorporates one or more integral socket-outlets; and has insulating sleeves on the line and neutral plug pins MS 589-3:2018 BS 1363 PT.3:1995 +A1 A2 A3
Integrated Adaptor PLUG TOP/PLUG (c) Adaptor extends supply from a socket-outlet; incorporates one or more integral socket-outlets; and has insulating sleeves on the line and neutral plug pins MS 1144:2017 BS 5733:2010+A1 2014
Travel Adaptor PLUG TOP/PLUG (c) Adaptor extends supply from a socket-outlet; incorporates one or more integral socket-outlets; and has insulating sleeves on the line and neutral plug pins No corresponding MS IEC 60884-1:2006; IEC 60884-2-5:1995
Electrical Connector (connecting device) PLUG TOP/PLUG (d) Connector Connecting devices for the connection of two or more electrical copper conductors MS IEC 60998-1:2005 IEC 60998-1:2002
Connecting device with screw type clamping unit PLUG TOP/PLUG (d) Connector Connecting devices for the connection of two or more electrical copper conductors MS IEC 60998-1:2005; MS IEC 60998-2-1:2005 IEC 60998-1:2002; IEC 60998-2-1:2002
Connecting device with screw-less type clamping unit PLUG TOP/PLUG (d) Connector Connecting devices for the connection of two or more electrical copper conductors MS IEC 60998-1:2005; MS IEC 60998-2-2:2005 IEC 60998-1:2002; IEC 60998-2-2:2002
Connecting device with insulation-piercing clamping units PLUG TOP/PLUG (d) Connector Connecting devices for the connection of two or more electrical copper conductors MS IEC 60998-1:2005; MS IEC 60998-2-3:2005 IEC 60998-1:2002; IEC 60998-2-3:2002
Twist-on connecting device PLUG TOP/PLUG (d) Connector Connecting devices for the connection of two or more electrical copper conductors MS IEC 60998-1:2005; MS IEC 60998-2-4:2005 IEC 60998-1:2002; IEC 60998-2-4:2002
Connecting boxes PLUG TOP/PLUG (d) Connector Connecting devices for the connection of two or more electrical copper conductors MS 1873:2005; MS 1873-22:2006 IEC 60670-1:2002 with modification; IEC 60670-22:2002 with modification
General Purpose Switch SWITCH AND DIMMER is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A MS IEC 60669-1:2012 IEC 60669-1:2007
Door Bell & Chime SWITCH AND DIMMER is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A MS IEC 61558-1:2005; MS IEC 61558-2-8:2007 IEC 61558-1:2009; IEC 61558-2-8:2010
Electronic Switch SWITCH AND DIMMER is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A MS IEC 60669-1:2012; MS IEC 60669-2-1:2012 IEC 60669-1:2007; IEC 60669-2-1:2009
Remote-control Switch SWITCH AND DIMMER is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A MS IEC 60669-1:2012; MS IEC 60669-2-2:2012 IEC 60669-1:2007; IEC 60669-2-2:2006
Time Delay Switch SWITCH AND DIMMER is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A MS IEC 60669-1:2012; MS IEC 60669-2-3:2012 IEC 60669-1:2007; IEC 60669-2-3:2006
Cooker Control Unit SWITCH AND DIMMER is an air-break switch; is for connection to the wiring of an electric installation; is primarily for mounting on a vertical surface; is manually opened and manually closed; and has a rating up to 63A No corresponding MS BS 4177:1992
Electric Shaver Socket Outlet SOCKET OUTLET (a) Socket Outlet is for fixing at a point at which fixed wiring terminates; provides a detachable connection with the pins of a plug; has two or more contacts; has a maximum rating of 15 A; with switch and without switch socket outlet MS IEC 61558-1:2005; MS IEC 61558-2-5:2006 IEC 61558-1:2009; IEC 61558-2-5:2010
13A Switch & unswitch socket outlet SOCKET OUTLET (a) Socket Outlet is for fixing at a point at which fixed wiring terminates; provides a detachable connection with the pins of a plug; has two or more contacts; has a maximum rating of 15 A; with switch and without switch socket outlet MS 589-2:2018 BS 1363:PT 2:1995 +A1 A2 A3
15A socket outlet & Plug SOCKET OUTLET (a) Socket Outlet is for fixing at a point at which fixed wiring terminates; provides a detachable connection with the pins of a plug; has two or more contacts; has a maximum rating of 15 A; with switch and without switch socket outlet MS 1577:2003 No corresponding international standard
Portable 2 pin socket outlet class II SOCKET OUTLET (a) Socket Outlet is for fixing at a point at which fixed wiring terminates; provides a detachable connection with the pins of a plug; has two or more contacts; has a maximum rating of 15 A; with switch and without switch socket outlet MS 1579:2003 No corresponding international standard
Portable cable reel SOCKET OUTLET (b) Portable A device comprising a flexible cable or cord attached to a reel so constructed that the flexible cable may be completely wound onto the reel, and provided with a plug and one or more socket outlets MS 1141:2006 IEC 61242:2008 with modification
Lamp holder for tubular fluorescent lamp FLUORESCENT LAMPHOLDER / STARTER HOLDER (a) Lamp Holder Holds tubular fluorescent lamp but does not include a lamp holder which by design is restricted to specific appliances MS IEC 60400:2006 IEC 60400:2004
Starter holder for tubular fluorescent lamp FLUORESCENT LAMPHOLDER / STARTER HOLDER (b) Starter Holder To hold a glow starter but does not include a starter holder which by design is restricted to specific appliances MS IEC 60400:2006 IEC 60400:2004
Ceiling Rose CEILING ROSE A terminal for connection to a lamp holder via a cable MS 770:1982 (confirmed 2006) BS 67:1969
Edison Screw Lamp holder CEILING ROSE Edison Screw Lamp holder with Edison screw thread E14, E27 and E40, designed for holding and connecting to the supply of lamps MS IEC 60238:2008 IEC 60238:2004
Bayonet cap Lampholder BAYONET CAP and MULTIWAYS ADAPTOR holds a bayonet cap lamp, bayonet cap adaptor; does not include a lamp holder restricted to specific appliances or for incorporation in industrial equipment No corresponding MS IEC 61184:2008+A1
Bayonet Lamp Adaptor BAYONET CAP and MULTIWAYS ADAPTOR holds a bayonet cap lamp, bayonet cap adaptor; does not include a lamp holder restricted to specific appliances or for incorporation in industrial equipment MS 769:1982 (confirmed 2013) with IEC 61184:2008 IEC 61184:2008 with modification
Fixed general purpose Luminaires (excluding Tube/Bulb); Batten Luminaires (excluding Tube/Bulb); Luminaires with self-ballasted fluorescent lamp LAMP FITTING (a) Luminaires provides illumination; incorporate electric light sources for operation from supply voltage up to 1000V MS IEC 60598-1:2012; MS IEC 60598-2-1:1997 (confirmed 2015) IEC 60598-1:2008; IEC 60598-2-1:1979
Recessed Luminaires (excluding Tube/Bulb) LAMP FITTING (a) Luminaires provides illumination; incorporate electric light sources for operation from supply voltage up to 1000V MS IEC 60598-1:2012; MS IEC 60598-2-2:1998 (confirmed 2011) IEC 60598-1:2008; IEC 60598-2-2:1997
Glow-starter for tubular fluorescent LAMP FITTING (b) Glow Starter is for starting pre-heat type fluorescent lamps; is a glow-start type; has an enclosure of insulating material; holds a light source or bulb MS IEC 60155:1996 IEC 60155:2006
with Edison screw or bayonet caps LAMP FITTING (c) Self-ballasted Compact Fluorescent Lamp (CFL) Lamp which cannot be dismantled without being permanently damaged, provided with a lamp cap incorporating a light source and any elements necessary for starting and stable operation MS IEC 60968:2006 (confirmed 2011); MS IEC 60969:2006 (confirmed 2015) IEC 60968:1999; IEC 60969:2001
MS IEC 61347-1:2012; MS IEC 61347-2-13:2012 LAMP FITTING (d) LED Lighting Lamp controlgear: Particular requirements for d.c. or a.c. supply electronic controlgear for LED modules IEC 61347-1:2010; IEC 61347-2-13:2006
MS IEC 60838-1:2008; MS IEC 60838-2-2:2008 LAMP FITTING (d) LED Lighting Lampholder (Connectors for LED-modules) IEC 60838-1:2004; IEC 60838-2-2:2006
MS IEC 62031:2011 with MS IEC 60061-1:2005 LAMP FITTING (d) LED Lighting Self-ballasted LED Modules for general Lighting services by voltage > 50V IEC 62031:2008+A1 A2 with IEC 60061-1:2005
MS IEC 62776:2017 LAMP FITTING (d) LED Lighting Self-ballasted double capped LED Lamps for general lighting services by voltage > 50V (to retrofit linear fluorescent lamp) IEC 62776:2014
MS IEC 62560:2012 LAMP FITTING (d) LED Lighting Self-ballasted single capped LED-lamps for general lighting services by voltage > 50V IEC 62560:2011
Capacitors for use in tubular fluorescent lamps and other circuits CAPACITOR for FLUORESCENT LAMP Is used together with a ballast in a lamp circuit MS IEC 61048:2006; MS IEC 61049:1999 (confirmed 2015) IEC 61048:1999; IEC 61049:1991
Magnetic Ballast for tubular fluorescent lamp BALLAST / CONTROL GEAR / DRIVER FOR LAMP (a) Ballast is for controlling the magnitude of current flowing through the discharge path of a fluorescent lamp; is of the independent or built-in type intended for use with luminaires; or is of the integral type; or is of the adaptor type MS IEC 61347-1:2012; MS IEC 61347-2-8:2003; MS 141:2014 with MS IEC 60921:2013 IEC 61347-1:2010; IEC 61347-2-8:2000; IEC 60921:2006 with modification
Electronic Ballast for fluorescent lamp BALLAST / CONTROL GEAR / DRIVER FOR LAMP (a) Ballast is for controlling the magnitude of current flowing through the discharge path of a fluorescent lamp; is of the independent or built-in type intended for use with luminaires; or is of the integral type; or is of the adaptor type MS IEC 61347-1:2012; MS IEC 61347-2-3:2003; MS IEC 60929:2008 with MS IEC 61000-3-2:2014 IEC 61347-1:2010; IEC 61347-2-3:2000; IEC 60929:2006 with IEC 61000-3-2:2009
Control Gear BALLAST / CONTROL GEAR / DRIVER FOR LAMP (b) Control Gear General safety for lamp controlgear for use on dc supply up to 250V and or ac supply up to 1000V MS IEC 61347-1:2012 IEC 61347-1:2010
Residual Current Circuit Breaker (RCCB) CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (a) Residual Current Device (RCD) isolates or initiates a tripping signal to isolate a low-voltage supply to protected circuits; has a rated residual current less than 300mA for fixed wiring or 10mA for other devices; has a rated load current not exceeding 125A for fixed wiring or 20A for other devices MS IEC 61008-1:2012; MS IEC 61008-2-1:2003 or MS IEC 61008-1:2012; MS IEC 61008-2-2:2003 IEC 61008-1:2010; IEC 61008-2-1:1990 or IEC 61008-1:2010; IEC 61008-2-2:1990
Residual Current Breaker with Overcurrent Protection (RCBO) CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (a) Residual Current Device (RCD) isolates or initiates a tripping signal to isolate a low-voltage supply to protected circuits; has a rated residual current less than 300mA for fixed wiring or 10mA for other devices; has a rated load current not exceeding 125A for fixed wiring or 20A for other devices MS IEC 61009-1:2012; MS IEC 61009-2-1:2003 or MS IEC 61009-1:2012; MS IEC 61009-2-2:2003 IEC 61009-1:2010; IEC 61009-2-1:1991 or IEC 61009-1:2010; IEC 61009-2-2:1991
Miniature Circuit Breaker (MCB) for ac supply CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse is an enclosed air-break switch; opens a low voltage circuit automatically under pre-determined conditions of overcurrent; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA MS IEC 60898-1:2007 IEC 60898-1:2003
Miniature Circuit Breaker (MCB) for ac & dc supply CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse is an enclosed air-break switch; opens a low voltage circuit automatically under pre-determined conditions of overcurrent; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA MS IEC 60898-2:2007 IEC 60898-2:2003
Fuse Base & Carrier up to 32A CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse is an enclosed air-break switch; opens a low voltage circuit automatically under pre-determined conditions of overcurrent; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA MS IEC 60269-1:2011; MS IEC 60296-2:2011 IEC 60269-1:2006; IEC 60269-2:2006
Fuse/Fuse Link up to 63A CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse is an enclosed air-break switch; opens a low voltage circuit automatically under pre-determined conditions of overcurrent; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA MS IEC 60269-2:2011; MS IEC 60269-3:2011 IEC 60269-2:2006; IEC 60269-3:2010